Panasonic AFP7PSA1 User Manual page 81

Cpu unit
Hide thumbs Also See for AFP7PSA1:
Table of Contents

Advertisement

Items
Master control relay (MCR)
Labels (JMP, LOOP)
Differential points (DF, DFI)
No. of step ladders
No. of subroutines
Interrupt program
Constant scan
Memory backup for power failure
Calendar timer
Self-diagnosis function
Rewriting during RUN function
Security function
(Note 1) The program capacity, data register capacity and maximum number of program blocks (PBs) vary according
to the type of CPU and memory configuration settings. They are set from the configuration menu of tool
software FPWIN GR7. The default values are pattern 3 for CPS4 and pattern 1 for CPS3.
Unit type
CPS4*
CPS3*
(Note 2) Figures in the table indicate the number of devices that can be used in the program. The actual inputs and
outputs that can be used vary by configuration.
(Note 3) Operation devices are categorized into "hold type", which memorizes the status immediately before power
failure or switch to the PROG. mode, and "non-hold type", which resets such status. Internal relays, data
registers, link relays and link registers can be set as non-hold type or hold type by the tool software. Counters
and error alarm relays are hold type. Other operation memories are non-hold type. However, data registers that
can be used as hold type are a maximum of 262,144 words.
(Note 4) Direct inputs (IN), direct outputs (OT), and unit memories (UM) are used by specifying unit slot numbers and
memory addresses to be controlled by instructions.
(Note 5) Battery lifetime: 3.3 years or more, suggested replacement interval: 5 years.
After power is supplied to the CPU unit for 30 minutes or longer, data can be retained for approx.one week by
the internal capactitor even without a battery.
(Note 6) Precision of the calendar timer (real-time clock): Difference less than 95 seconds per month (0C), less than
15 seconds per month (+25C), less than 130 seconds per month (+55C).
When the unit is connected to ET-LAN, the time is synchronized by the SNTP function.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
No limits (no numbers)
Max. 65,535 points per PB
Depending on the program capacity
No restriction
Max. 65,535 points per PB
Fixed cycle execution type PB: 1 PB/per project
Execution interval unit: 0.1 ms or 1 ms
Interrupt from High-speed counter unit
Max. 8 points per unit, Max. 8 units per project
0.5 to 125 ms
Built-in non-volatile memory backs up the project (program,
comments and configuration data) and operation memory. (Excluding
calendar timer)
Yes (a separately sold backup battery is required) (Note 5) (Note 6)
Watchdog timer, program syntax check
Yes (rewriting on a PB basis, no limit to the number of rewriting steps)
Password function, no-read settings, encryption can be set for the
program, comments and configuration data
Memory type
Program capacity (step)
Data register capacity
(word)
Maximum number of PBs
Program capacity (step)
Data register capacity
(word)
Maximum number of PBs
8.1 CPU Unit Specifications
Description
Memory select pattern
1
2
234,000
221,500
196,000
65,536
131,072
262,144
468
443
121,500
96,000
131,072
262,144
425,984
243
192
3
4
144,500
51,500
524,288
999,424
392
289
64,000
32,000
589,824
128
64
5
103
8-5