Specifications

8.1.4 Operation Memory Area

Name
External input
External
output
Internal relay
Link relay
Timer
Counter
System relay
Pulse relay
Error alarm
relay
Direct input
Direct output
External input
(Note1)
External
(Note1)
output
Internal relay
Link relay
Data register
Link register
Unit memory
System data
register
8-8
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Usable devices and ranges
X
8,192 points (X0 to X511F) (Note 1)
Y
8,192 points (Y0 to Y511F) (Note 1)
R
32,768 points (R0 to R2047F) (Note 2)
L
16,384 points (L0 to L1023F) (Note 2)
T
4,096 points (T0 to T4095) (Note 2)
C
1,024 points(C0 to C1023) (Note 2)
Approx. 1120 points
SR
(approx. 70 words)
P
4,096 points (P0 to P255F)
E
4,096 points (E0 to E4095)
Can allocate input numbers to each
IN
slot (IN0 to IN62F) (Note 3)
Can allocate output numbers to each
OT
slot (OT0 to OT62F) (Note 3)
WX
WX0 to WX511 (Note 1)
WY
WY0 to WY511 (Note 1)
WR
WR0 to WR2047 (Note 2)
WL
WL
b0 to WL1023
Max. DT 999424 words
DT
(DT0 – DT999423) (Note 2) (Note 4)
16,384 words (LD0 to LD16383)
LD
(Note 2)
UM
Max. 512K words per unit (Note 3)
SD
Approx. 110 words
Functions
Turns on or off based on external input.
Externally outputs on or off state.
Relay which turns on or off only within
program.
This relay is a shared relay used for PLC
link.
This goes on when the timer reaches the
specified time.
This goes on when the timer increments.
Relay which turns on or off based on
specific conditions and is used as a flag.
This relay only turns on during one scan at
the start of the execution condition.
This relay ensures that error conditions
that are freely allocated by the user are
memorized in the memory.
This relay is for input/output processing
during operation, without depending on
usual I/O refresh.
Code for specifying 16 external input
points as one word (16 bits) of data.
Code for specifying 16 external output
points as one word (16 bits) of data.
Code for specifying 16 internal relay points
as one word (16 bits) of data.
Code for specifying 16 link relay points as
one word (16 bits) of data.
Data memory used in program.
Data is handled in 16-bit units (one word).
This is a shared data memory which is
used within the PLC link. Data is handled
in 16-bit units (one word).
This device is for accessing the unit
memory of intelligent units. Its size varies
by unit, and is allocated by default.
Data memory for storing specific data.
Various settings and error codes are
stored.