Technical Specifications
Item
Gas Input
kW Output
Appliance Inlet Pressure
ATPP Burner
pressure
Main Burner Injector Ø
Pilot injector Ø (SIT pilot number)
Gas Control
Ignition module assembly
Gas Connection
Pilot assembly
Internal gas piping
Remote control
Weight, (Engine only)
Convection Fan
Glass – Primary
Glass – Secondary (Dress Guard)
Glass seal material
Electrical connection – cord
Power Consumption
Fuse
Temperature range
Decibel level
Flue – Masonry. (If required)
Flue – Freestanding & Zero
Clearance
RIB2312 Sapphire Gas Log Flame Fire
Natural Gas
High
Low
1.13kPa
High
0.71kPa
Low
0.15KPa
2.80mm
(Threaded Hex
Brass)
# 62
Double Ø160mm x 180mm - 2 speed - Centrifugal
Woven fibreglass chord – Hytex
230-240V 50Hz 7.5Amps 3pin plug + ~1.5m Lead. Cert
Less than 50W Normal Operation. Less than 3W on
Twin skinned Ø100mm x Ø150mm outer
- 4 -
Description
Propane
30.0 MJ/h
16.5 MJ/h
6.97 kW
2.75kPa
2.25kPa
0.50kPa
1.55mm (Threaded Hex Brass)
Rinnai Universal Control
Rinnai Ignitor E1-0218
1/2" BSPT Male brass fitting.
Pilot – SIT 190 series
Pilot - 6mmØ x 1.0mm aluminium
Burner - 8mmØ x 1.0mm aluminium
IR remote control
60kgs
Ceramic Glass
Tempered Glass
®
1000 by Mid Mountain
USA
#18070
Standby.
3Amp 250V glass fuse
7°C -32°C
Hi ~ Lo=45 ~ 37dB(A
Flexi Liner Ø100mm
AGA #4198
ULPG
25.0 MJ/h
13.5 MJ/h
5.63 kW
2.75 kPa
1.70 kPa
0.50 kPa
#35
1/03/18 ©Rinnai