Rinnai RIB2312 Service Manual page 21

Gas log flame fire
Table of Contents

Advertisement

240 Volt exposure. Isolate the electrical supply to the appliance and reconfirm with the
neon screwdriver or multimeter. Disconnect gas supply.
All work should be carried out by qualified service technician
4) Removal of Front Panel Glass &
'Standoff's'
a. Lay front panel assembly face down on soft cloth
surface.
b. Remove 'Standoff's' x 4 screws, (Refer to Image
5).
c. Remove front panel, glass with 'Standoff's'
attached will remain on the bench.
d. Remove 'Standoff's' with rubber pads.
e. For replacement of rubber pads and glass follow
steps a. - d. in reverse order.
5) Removal of Combustion Chamber Glass
a. Remove glass surround, by lifting bottom section
forward and up. (Refer to image 6).
b. Remove 2 x M5 screws from Top Glass
Retainer.
c. Loosen 2 x M5 screws from Bottom Glass
Retainer.
d. Lift Glass out of Bottom Glass Retainer.
(Refer to Image 7).
6) Removal of the Burner
a. Remove log set.
b. Remove 1 x screw from right hand end of burner.
c. Slide Burner to the right to slide it off from
Injector. (Refer to Image 8).
RIB2312 Sapphire Gas Log Flame Fire
CAUTION
- 16 -
Image 5
Image 6
Image 7
Image 8
1/03/18 ©Rinnai