Commissioning the Appliance for different gas type
240 VOLTS, RISK OF ELECTRICAL SHOCK! Exercise caution as there is potential for electric
shock from the exposed wiring and circuitry when panels are removed..
WARNING
DO NOT leave the appliance unattended when the power is connected and the panels are
removed.
This appliance is factory set for the correct gas type as per it's gas type labelling, re-commissioning for gas type
will only be required if the PCB is being replaced or if it has undergone a gas type conversion, I.e.; from NG to
Propane or vice versa. Commissioning of the gas is carried out via the PCB.
Commissioning of the PCB must be carried out BEFORE the gas pressures are checked.
NOTE
1. Turn on the gas and power supply to the appliance.
2. With the appliance OFF, press the 'TEST' button
3. Press the 'UP' button
the table below for correct gas type code.
4. Press the 'Set' button
5. Gas pressure settings should now be checked as per steps 1 and 3 above.
RIB2312 Sapphire Gas Log Flame Fire
or 'DOWN' button
8
13
Natural Gas
A1
to lock in the code.
11
- 13 -
the gas type code will be shown on the display
6
to obtain the correct gas type code for the appliance. Refer to
Propane Gas
L1
.
14