240 Volt exposure. Isolate the electrical supply to the appliance and reconfirm with the
neon screwdriver or multimeter. Disconnect gas supply.
All work should be carried out by qualified service technician
O
PERATIONS THAT REQUIRE REMOVAL OF
11) Combustion Chamber Removal
a. Remove 8 x screws from the bottom of the
Combustion Chamber. (Refer to Image 17).
b. Disconnect overheat loom, right hand side of
the combustion chamber.
c. Remove 3 x screws from the top of the
Combustion Chamber. (Refer to Image 18).
d. Lift Combustion Chamber out. (Refer Image 19).
e. Remove overheat switch from rear right hand
side of Combustion Chamber. (Refer Image 20).
RIB2312 Sapphire Gas Log Flame Fire
CAUTION
C
OMBUSTION
- 19 -
C
HAMBER
Image 17
Image 18
Image 19
Image 20
1/03/18 ©Rinnai