Firmware Upgrade Screen - ZyXEL Communications PLA5236 User Manual

1000 mbps powerline ac900 wireless extender
Hide thumbs Also See for PLA5236:
Table of Contents

Advertisement

Table 28 Maintenance > Time
L ABEL
Daylight Savings
Start Date
End Date
Apply
Cancel
11.6 Firm wa re Upg ra de Sc re e n
Find firmware at
extension, e.g., "PLA.bin". The upload process uses HTTP (Hypertext Transfer Protocol) and may take up
to two minutes. After a successful upload, the system will reboot.
Click
Ma inte na nc e > Firm wa re Upg ra de
PLA.
Chapter 11 Maintenance
DESC RIPT IO N
Daylight saving is a period from late spring to fall when many countries set their clocks
ahead of normal local time by one hour to give more daytime light in the evening.
Select this option if you use Daylight Saving Time.
Configure the day and time when Daylight Saving Time starts if you selected
. The
field uses the 24 hour format. Here are a couple of examples:
Sa ving s
o 'c lo c k
Daylight Saving Time starts in most parts of the United States on the second Sunday of
March. Each time zone in the United States starts using Daylight Saving Time at 2 A.M. local
time. So in the United States you would select
field.
o 'c lo c k
Daylight Saving Time starts in the European Union on the last Sunday of March. All of the
time zones in the European Union start using Daylight Saving Time at the same moment (1
A.M. GMT or UTC). So in the European Union you would select
you type in the
o 'c lo c k
would type 2 because Germany's time zone is one hour ahead of GMT or UTC (GMT+1).
Configure the day and time when Daylight Saving Time ends if you selected
. The
field uses the 24 hour format. Here are a couple of examples:
Sa ving s
o 'c lo c k
Daylight Saving Time ends in the United States on the first Sunday of November. Each time
zone in the United States stops using Daylight Saving Time at 2 A.M. local time. So in the
United States you would select
Daylight Saving Time ends in the European Union on the last Sunday of October. All of the
time zones in the European Union stop using Daylight Saving Time at the same moment (1
A.M. GMT or UTC). So in the European Union you would select
time you type in the
o 'c lo c k
would type 2 because Germany's time zone is one hour ahead of GMT or UTC (GMT+1).
Click
to save your changes back to the PLA.
Apply
Click
to reload the previous configuration for this screen.
C a nc e l
www.zyxel.com
in a file that (usually) uses the system model name with a "*.bin"
. Follow the instructions in this screen to upload firmware to your
PLA5236 User's Guide
Se c o nd
field depends on your time zone. In Germany for instance, you
,
,
First
Sunda y
No ve m b e r
field depends on your time zone. In Germany for instance, you
59
Da ylig ht
,
,
and type 2 in the
Sunda y
Ma rc h
,
,
L a st
Sunda y
Ma rc h
Da ylig ht
and type 2 in the
o 'c lo c k
,
,
L a st
Sunda y
O c to b e r
. The time
field.
. The

Advertisement

Table of Contents
loading

Table of Contents