Fitting the FPA15
board
(continued)
Fig.14
(66)
Fig.15
(6)
Fig.16
Fig.17
(68)
(55)
(72)
(73)
(5)
(40)
(41)
72
- Fasten the X3 cable (blue) (72) and
the by-pass capacitors (73) onto the
copper bracket (55), using the 5x12 -
TX20 screw (68)
- Tighten the 5x12 - TX20 screw (68)
with a torque of 2 Nm
- Thigthen the round nut (66)
- Replace the setting dial (6)
Note! When thigthening the
fixing nut for the "Welding-
amperage setting dial", hold the
dial (6) firmly
- Thigthen the fixing nut of the setting
dial (6) with the socket spanner (width-
across 7)
- Replace the cap to the "Welding-
amperage setting dial" (6)
- Plug the 10-pole Molex plug (41) onto
(42)
board LCA15
- Plug the 2-pole Molex plug (40) onto
board LCA15
- Arrange the ribbon cable (42) above
the cable harness, as shown in Fig.17
- Plug the ribbon cable (42) to board
FPA15 (5)