Summary of Contents for Equinox Systems Vortex

  • Page 1 Vortex User Manual Order code: EQLED073...
  • Page 2: Safety Advice

    NO USER SERVICEABLE PARTS. pulling the power-cable. • This lighting fixture is for professional use only - it is • Make sure that the available mains supply voltage is not designed for or suitable for household use. The between 100~240V AC, 50/60Hz. product must be installed by a qualified technician in accordance with local territory regulations. The safety of • Make sure that the power cable is never crimped or the installation is the responsibility of the installer. The damaged. Check the equipment and the power cable fixture presents risks of severe injury or death due to fire periodically. hazards, electric shock and falls. • If the equipment is dropped or damaged, disconnect the • Warning! Risk Group 2 LED product according to mains power supply immediately and have a qualified EN 62471. Do not view the light output with optical engineer inspect the equipment before operating again. instruments or any device that may concentrate the beam. • WARRANTY: One year from date of purchase. OPERATING DETERMINATIONS If this equipment is operated in any other way, than those described in this manual, the product may suffer damage and the warranty becomes void. Incorrect operation may lead to danger e.g: short-circuit, burns and electric shocks etc. Do not endanger your own safety and the safety of others! Incorrect installation or use can cause serious damage to people and/or property. www.prolight.co.uk Vortex User Manual...
  • Page 3 7480 4780 21500 5370 2390 1340 39200 9809 4360 2450 1570 10200 2560 1140 58000 14540 6440 3630 2320 60° - Lux FULL ON 11000 2738 1220 2140 85.4 3600 58.8 37.6 5080 1270 5° 60° www.prolight.co.uk Vortex User Manual...
  • Page 4: Technical Specifications

    F2A 250V POWER INPUT: POWER OUTPUT: MENU DOWN UP ENTER 100-240V~50/60Hz 100-240V~50/60Hz In the box: 1 x fixture, 01 - OLED display 04 - 3-Pin DMX input 07 - PowerCON output 1 x omega clamp, 1 x power cable 02 - Function buttons 05 - 3-Pin DMX output 08 - Fuse F2A 250V & 1 x user manual 03 - Microphone 06 - PowerCON input 09 - Fan cooling vents www.prolight.co.uk Vortex User Manual...
  • Page 5: Control Panel Menu

    Operating instructions Control Panel Menu: The OLED control panel situated on the front of the fixture allows the user to access the menu system to adjust the fixtures settings. When the unit has been powered on it will show “Equinox Vortex Resetting”. The fixture will then return to its home screen. To access the main menu press the “ENTER” button and use the “UP” and “DOWN” buttons until the menu required is highlighted. Pressing the “ENTER” button on one of these options allows you to access the sub menu where you use the “UP” and “DOWN” buttons to select the option/value required. Once the option/value has been selected press the “ENTER” button once more to confirm the setting. Main Menu Sub Menu Options/Values Description (Default Settings in BOLD) 1. DMX Address 001-512 DMX Address Setting DMX 17 Ch (17 channel mode) DMX Channel Setting DMX 10 Ch (10 channel mode) 2. Running MODE Auto Auto Mode Sound Sound Mode Slave Slave Mode 3. Auto Prog...
  • Page 6: Dmx Channel Modes

    Effect lens clockwise rotation (slow-fast) 000-010 No function 011-020 021-030 Green 031-040 Blue 041-050 White 051-060 Pastel Red 061-070 Pastel Green 071-080 Pastel Blue 081-090 Yellow 091-100 Cyan 101-110 Magenta 111-120 Pastel Yellow 121-130 Pastel Cyan 131-140 Pastel Magenta 141-150 White (RGBW) 151-200 Colour change (slow-fast) 201-247 Colour fade (slow-fast) 248-255 Colour change (sound activated) www.prolight.co.uk Vortex User Manual...
  • Page 7 040-069 Zoom program 2 070-099 Zoom program 3 100-129 Zoom program 4 130-159 Zoom program 5 160-189 Zoom program 6 190-219 Zoom program 7 220-255 Zoom program 8 000-007 No function 008-060 Pan/tilt program 1 061-100 Pan/tilt program 2 101-140 Pan/tilt program 3 141-180 Pan/tilt program 4 181-255 Pan/tilt (sound activated) 000-050 No function 051-100 Fast speed (10S) 101-150 No function 151-200 Slow speed (10S) 201-255 Reset (10S) www.prolight.co.uk Vortex User Manual...
  • Page 8: Installation

    Installation Installation: 1) Bolt each clamp to the Omega bracket(s) with the bolt and locking nut throughout the hole in the bracket. 2) Fasten the Omega bracket(s) to the bottom of the moving head base by inserting the quick lock fasteners into the receiving holes in the base and tighten. 3) Hang the fixture to the support through the clamp and secure with the locking nuts. Fasten the safety cable through the bottom of the base and over the support. Attention: • Always ensure that the structure to which you are attaching the fixture is secure and able to support a weight of 10 times the fixtures weight. • Always use a safety cable that cab hold 12 times the weight of the fixture when installing. • Make sure that the fixture is firmly attached in a way that no vibrations or movement could occur during operation. • The equipment must be installed by professionals and must be installed in an area where it is out of reach of people and no one can pass by or under it. www.prolight.co.uk Vortex User Manual...
  • Page 9: Dmx Setup

    DATA cable (DMX cable) requirements (for DMX operation): This fixture can be controlled via DMX-512 protocol. The DMX address is set on the back of the unit. Your unit and your DMX controller require a standard 3-pin XLR connector for data input/output, see image below. Further DMX cables can be purchased from all good sound and lighting suppliers or Pro Light Concepts dealers. Please quote: CABL10 – 2m CABL11 – 5m CABL12 – 10m Note: DMX cable must be daisy chained and cannot be split. www.prolight.co.uk Vortex User Manual...
  • Page 10: Line Termination

    5-pin XLR (male) 3-pin XLR (female) Pin 1: GND (screen) Pin 1: GND (screen) Pin 2: Signal (-) Pin 2: Signal (-) Pin 3: Signal (+) Pin 3: Signal (+) Pin 4: N/C Pin 5: N/C www.prolight.co.uk Vortex User Manual...
  • Page 11: Weee Notice

    WEEE notice Correct Disposal of this Product (Waste Electrical & Electronic Equipment) (Applicable in the European Union and other European countries with separate collection systems) This marking shown on the product or its literature, indicates that it should not be disposed with other household wastes at the end of its working life. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources. Household users should contact either the retailer where they purchased this product, or their local government office, for details of where and how they can take this item for environmentally safe recycling. Business users should contact their supplier and check the terms and conditions of the purchase contract. This product should not be mixed with other commercial wastes for disposal. www.prolight.co.uk Vortex User Manual...
  • Page 12 Vortex User Manual...