Alcatel-Lucent 7750 SR OS Interface Configuration Manual page 367

7750 sr series
Hide thumbs Also See for 7750 SR OS:
Table of Contents

Advertisement

The no form of this command resets the MRRU to the default.
Default
1524
Parameters
bytes — Specify the maximum received reconstructed unit size, expressed as an integer.
protect-bundle
Syntax
[no] protect-bundle bundle-id
Context
config>port>multilink-bundle
Description
This command configures a protect bundle that is part of this BPGrp.
Parameters
bundle-id — Specifies the protection multilink bundle in the bundle protection group. The command
red-differential-delay
Syntax
red-differential-delay red-diff-delay [down]
no red-differential-delay
Context
config>port>multilink-bundle
Description
This command sets the maximum acceptable differential delay for individual links within a multilink
bundle. The differential delay is calculated as the round-trip differential delay for MLPPP bundles,
and as uni-directional differential delay for IMA bundles.
The no form of this command restores the red-differential-delay defaults.
Default
None
Parameters
red-diff-delay — Specify the maximum red differential delay value.
down — Transition the link that exceeded the differential delay to a down state (for example, remove
7750 SR OS Interface Configuration Guide
Values
1500 — 9206 bytes
syntax must be configured as follows:
Syntax:
bundle-type-slot/mda.bundle-num
bundle-PPP or IMA-slot/mda.bundle-num (Creates an MLPPP or IMA bundle.)
bundle:
slot:
bundle-num:
For example:
router1>config>port>ml-bundle> protect-bundle bundle-ima-1/1.1
Values
0 — 25 milliseconds for all other bundles
0 — 50 milliseconds for IMA bundles
it from the multilink bundle from an operational perspective).
keyword
IOM/MDA slot numbers
1 — 256
Interface Configuration
Page 367

Advertisement

Table of Contents
loading

Table of Contents