Technical specifications
Switching cycle:
Relay:
Withstand voltage:
Temperature glow wire test:
Temperature ball pressure test: 125 °C
Construction:
Degree of pollution:
Degree of protection:
Protection class:
Ambient temperature:
Dimensions (W x H x D):
Weight:
Radio frequency:
Receiver category:
Typ. open area RF range:
Duty cycle:
Subject to technical changes.
66
10000
Changeover contact,
1-pole, µ contact
NO contact, 1-pole, µ
contact
2500 V
850 °C
Independently
mounted
electronic regulation
and control device
2
IP20
I
0 - 50°C
199 x 156 x 34 mm
365 g
868.3 MHz/869.525
MHz
SRD category 2
380 m
< 1% per h/< 10% per h