2.0

Scope

Guides the user through tools and equipment required for unpacking and performing connections required for initial
installation. Included are the electrical specifications, environmental recommendations and connection details.
The following describes installation procedures and recommendations for the Galaxy 3000 10-30 kVA UPS including
receiving, handling, and storage procedures. Prerequisites prior to installation; installation procedures and start-up
procedures are also included.
2.1

Electrical Specifications

Environmental Recommendations

Recommended environment 20° to 25° C (68° to 77° F.); 50% relative humidity; computer room or other tempera-
Operating temperature
Storage
Humidity
Altitude
Acoustic noise
Table 2-1: Electrical Specifications for the Galaxy 3000.
Output Power Rating (0.8 PF)
UPS Voltage (input / output)
Input / Output Requirements & Frequency
Input Phase Rotation
Input Power Factor
Max. Nominal Input Current (-15% Input Line at 100% Load)
Output Current
DC Voltage
Max. Battery Current at Nominal Battery Voltage (240 VDC at 100% Load)
Max. Battery Current at Battery End-Voltage (198 VDC at 100% Load)
Battery Disconnect Current
Max. System Heat Generation (BTU/hr)
SR1 Maintenance Bypass and Isolation Switch Rating
Input / Output Fuse Current
Input and Optional Bypass Contactor Current
Output Power Rating (0.8 PF)
UPS Voltage (input / output)
Input / Output Requirements & Frequency
Input Phase Rotation
Input Power Factor
Max. Nominal Input Current (-15% Input Line at 100% Load)
Output Current
DC Voltage
Max. Battery Current at Nominal Battery Voltage (240 VDC at 100% Load)
Max. Battery Current at Battery End-Voltage (198 VDC at 100% Load)
Battery Disconnect Current
Max. System Heat Generation (BTU/hr)
SR1 Maintenance Bypass and Isolation Switch Rating
Input / Output Fuse Current
Input and Optional Bypass Contactor Current
*
NOTE: Interrupted Transfer to Bypass Source:
If the bypass source is beyond the conditions stated below, the UPS will make an interrupted transfer (not more than 500 msec. in duration).
1.
Bypass voltage greater than +10%, -10% from the UPS rated output voltage.
2.
Bypass frequency greater than ±2 Hz from the UPS rated output frequency.
86-172010-00 C05
ture- and humidity-controlled environment
0° to 40° C (32° to 104° F.) except battery
-20° to 50° C (-4° to 122° F.)
up to 90% non-condensing (operating)
sea level to 3,000 meters without derating
78 dBA Acoustic noise at rated load as measured 5 feet from the front of the UPS
module
208/208
220/220
31 A
31 A
28 A
26 A
198 VDC End Voltage
39 ADC
41 ADC
48 ADC
49 ADC
63 A (7 min. back-up time)
4777
6824
50 A
50 A
70A
70A
40A
40A
208/208
220/220
61 A
61 A
56 A
53 A
198 VDC End Voltage
78 ADC
80 ADC
94 ADC
97 ADC
8871
12965
100 A
100 A
125A
125A
110A
110A
Installation
10 kVA
480/208
480/480
600/208
208/208
Three Phase, Three Wire + N + G
A,B,C Clockwise
>.98
14 A
14 A
11 A
46 A
28 A
12 A
28 A
42 A
240 VDC Nominal
277 VDC Max. Maintenance Voltage
39 ADC
41 ADC
39 ADC
59 ADC
48 ADC
49 ADC
48 ADC
71 ADC
70 A (>7 min. back-up time)
5800
6824
5800
7165
50 A
50 A
50 A
50 A
70A
70A
70A
70A
40A
40A
40A
40A
20 kVA
480/208
480/480
600/208
208/208
Three Phase, Three Wire + N + G
A,B,C Clockwise
>.98
27 A
28 A
22 A
91 A
56 A
24 A
56 A
83 A
240 VDC Nominal
277 VDC Max. Maintenance Voltage
78 ADC
80 ADC
78 ADC
116 ADC
94 ADC
97 ADC
94 ADC
141 ADC
125 A
10918
12965
10918
13306
100 A
100 A
100 A
100 A
125A
125A
125A
125A
110A
110A
110A
110A
Installation
15 kVA
220/220
480/208
480/480
600/208
60 Hz
46 A
21 A
21 A
17 A
39 A
42 A
18 A
42 A
61 ADC
59 ADC
61 ADC
59 ADC
74 ADC
71 ADC
74 ADC
71 ADC
10235
8871
10235
8871
50 A
50 A
50 A
50 A
70A
70A
70A
70A
40A
40A
40A
40A
30 kVA
220/220
480/208
480/480
600/208
60 Hz
91 A
41 A
42 A
33 A
79 A
83 A
36 A
83 A
120 ADC
116 ADC
120 ADC
116 ADC
146 ADC
141 ADC
146 ADC
141 ADC
19447
16377
19447
16377
100 A
100 A
100 A
100 A
125A
125A
125A
125A
110A
110A
110A
110A
2 — 1