SERVICING
7 SEGMENT LED
(characters will alternate)
(no display)
On
Ec
E5
EF
d0
d1
d4
b0
b1
b2
b3
b4
b5
b6
b7
b9
C1
C2
P1
P2
h1
h2
FC
FH
F
H1
H2
dF
GREEN CFM LED - EACH FLASH REP RESENTS 100CFM (USE FOR AIRFLOW APPROXIMATION
40
DES CRIPTION OF CONDITION
INTERNAL CONTROL FAULT / NO POWER
STANDBY, WAITING FOR INPUTS
HEATER KIT TOO LARGE, TOO SMALL, OR NO MATCH
FUSE OPEN
AUXILIARY SWITCH OPEN
DATA NOT ON NETWORK
INVALID DATA ON NETWORK
INVALID MEMORY CARD DATA
BLOWER MOTOR NOT RUNNING
BLOWER MOTOR COMMUNICATION ERROR
BLOWER MOTOR HP MISMATCH
BLOWER MOTOR OPERATING IN POWER, TEMP., OR SPEED
LIMIT
BLOWER MOTOR CURRENT TRIP OR LOST ROTOR
BLOWER MOTOR ROTOR LOCKED
OVER/UNDER VOLTAGE TRIP OR OVER TEMPERATURE TRIP
INCOMPLETE PARAMETER SENT TO MOTOR
LOW INDOOR AIRFLOW
LOW STAGE COOL - LEGACY MODE ONLY
HIGH STAGE COOL - LEGACY MODE ONLY
LOW STAGE HEAT PUMP HEAT - LEGACY MODE ONLY
HIGH STAGE HEAT PUMP HEAT - LEGACY MODE ONLY
EMERGENCY HEAT LOW - COMMUNICATING MODE ONLY
EMERGENCY HEAT HIGH - COMMUNICATING MODE ONLY
FAN COOL - COMMUNICATING MODE ONLY
FAN HEAT - COMMUNICATING MODE ONLY
FAN ONLY
ELECTRIC HEAT LOW
ELECTRIC HEAT HIGH
DEFROST - COMMUNICATING MODE ONLY
(Note: defrost is displayed as H1 in a legacy setup)
ONLY) - EXAMPLE: 8 FLASHES = 800CFM