Download Print this page
Goodman ASXC160361A Technical Manual

Goodman ASXC160361A Technical Manual

Sxc 16 seer

Advertisement

TECHNICAL MANU
TECHNICAL MANU AL
TECHNICAL MANU
TECHNICAL MANU
TECHNICAL MANU
Refer to Service Manual RS6200006 for installation, operation, and troubleshooting information.
All safety information must be followed as provided in the Service Manual.
Refer to the appropriate Parts Catalog for part number information.
See models on page 3.
This manual is to be used by qualified, professionally trained HVAC technicians only. Goodman does
not assume any responsibility for property damage or personal injury due to improper service
procedures or services performed by an unqualified person.
*SXC 16 SEER
Condensing Units
Copyright © 2009-2014 Goodman Manufacturing Company, L.P.
AL
AL
AL
AL
RT6114004r11
August 2014

Advertisement

loading

Summary of Contents for Goodman ASXC160361A

  • Page 1 • See models on page 3. RT6114004r11 This manual is to be used by qualified, professionally trained HVAC technicians only. Goodman does not assume any responsibility for property damage or personal injury due to improper service August 2014 procedures or services performed by an unqualified person.
  • Page 2: Product Identification

    WARNING Disconnect ALL power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury or death. Goodman will not be responsible ONLY individuals meeting (at a WARNING WARNING...
  • Page 3 WARNING that is not design certified by damage, personal injury, or death, Goodman for use with this unit. do not store combustible materials or use gasoline or Serious property damage, personal injury, reduced unit other flammable liquids or vapors in the vicinity of this performance and/or hazardous conditions may result appliance.
  • Page 4: Product Design

    PRODUCT DESIGN Models covered by this manual come with a new 4-wire com- Operating pressures and amp draws may differ from stan- municating PCB. When paired with a compatible communi- dard reciprocating and/or scroll compressors. This informa- cating indoor unit and a communicating thermostat, these tion may be found in the "Cooling Performance Data"...
  • Page 5 CONDENSING UNIT SPECIFICATIONS A/DSXC160[24-60]1A* Dimensions M odel Dim ens ions - W x D x H *SXC 16 0 2 41 A* 2 9 x 2 9 x 3 2 ¼ *SXC 16 0 3 61 A* 2 9 x 2 9 x 3 8 ¼ *SXC 16 0 4 81 A* 35 ½...
  • Page 6 CONDENSING UNIT SPECIFICATIONS ASXC160[24-36]1B* Dimensions Model Dimensions - W x D x H ASXC160241B* 29 x 29 x 30¼ ASXC160361B* 29 x 29 x 30¼ AS XC160241BB A S XC160241B C A SXC160361B B AS XC160361BC Cooling Capacity, B TUH 24,000 24,000 36,000...
  • Page 7 CONDENSING UNIT SPECIFICATIONS ASXC160[48-60]1B* Dimensions Model Dimensions - W x D x H ASXC160481B* 35½ x 35½ x 36¼ ASXC160601B* 35½ x 35½ x 38¼ ASXC160481B* ASXC160481BC AS XC160601B* A SXC160601BC Cooling Capacity , BTUH 48,000 48,000 60,000 60,000 Com pres sor R.L.
  • Page 8 CONDENSING UNIT SPECIFICATIONS DSXC160[24-36]1A* Dimensions Model Dimensions - W x D x H DSXC160241A* 29 x 29 x 30¼ DSXC160361A* 29 x 29 x 30¼ DSXC160241AB DSXC160241AC DSXC160361AB DSXC160361AC Cooling Capacity, BTUH 24,000 24,000 36,000 36,000 Compressor R.L. Amps 10.3 11.7 16.7 15.3...
  • Page 9 CONDENSING UNIT SPECIFICATIONS DSXC160[48-60]1B* Dimensions Model Dimensions - W x D x H DSXC160481B* 35½ x 35½ x 36¼ DSXC160601B* 35½ x 35½ x 38¼ DSXC160481B* DSXC160481BC DSXC160601B* DSXC160601BC Cooling Capacity, BTUH 48,000 48,000 60,000 60,000 Compressor R.L. Amps 21.2 21.2 25.6 28.8...
  • Page 10 ASXC160241A*-LOW STAGE PERFORMANCE DATA...
  • Page 11 PERFORMANCE DATA ASXC160241A*-LOW STAGE...
  • Page 12 PERFORMANCE DATA ASXC160241B*-LOW STAGE...
  • Page 13 PERFORMANCE DATA ASXC160241B*-LOW STAGE Same as ASX160241C...
  • Page 14 PERFORMANCE DATA ASXC160361A*-LOW STAGE...
  • Page 15 PERFORMANCE DATA ASXC160361A*-LOW STAGE...
  • Page 16 PERFORMANCE DATA ASXC160361B*-LOW STAGE...
  • Page 17 PERFORMANCE DATA ASXC160361B*-LOW STAGE...
  • Page 18 A/DSXC160481A*-LOW STAGE PERFORMANCE DATA...
  • Page 19 A/DSXC160481A*-LOW STAGE PERFORMANCE DATA...
  • Page 20 PERFORMANCE DATA *SXC160481B*-LOW STAGE...
  • Page 21 PERFORMANCE DATA *SXC160481B*-LOW STAGE...
  • Page 22 *SXC160601A*-LOW STAGE PERFORMANCE DATA...
  • Page 23 PERFORMANCE DATA *SXC160601A*-LOW STAGE...
  • Page 24 PERFORMANCE DATA *SXC160601B*-LOW STAGE...
  • Page 25 PERFORMANCE DATA *SXC160601B*-LOW STAGE...
  • Page 26 COOLING PERFORMANCE DATA ASXC160241A*-HIGH STAGE...
  • Page 27 COOLING PERFORMANCE DATA ASXC160241A*-HIGH STAGE...
  • Page 28 COOLING PERFORMANCE DATA ASXC160241B*-HIGH STAGE...
  • Page 29 COOLING PERFORMANCE DATA ASXC160241B*-HIGH STAGE...
  • Page 30 COOLING PERFORMANCE DATA ASXC160361A*-HIGH STAGE...
  • Page 31 COOLING PERFORMANCE DATA ASXC160361A*-HIGH STAGE...
  • Page 32 COOLING PERFORMANCE DATA ASXC160361B*-HIGH STAGE...
  • Page 33 COOLING PERFORMANCE DATA ASXC160361B*-HIGH STAGE...
  • Page 34 COOLING PERFORMANCE DATA *SXC160481B*-HIGH STAGE...
  • Page 35 COOLING PERFORMANCE DATA *SXC160481B*-HIGH STAGE...
  • Page 36 COOLING PERFORMANCE DATA *SXC160601A*-HIGH STAGE...
  • Page 37 COOLING PERFORMANCE DATA *SXC160601A*-HIGH STAGE...
  • Page 38 COOLING PERFORMANCE DATA A/DSXC160601B*-HIGH STAGE...
  • Page 39 COOLING PERFORMANCE DATA A/DSXC160601B*-HIGH STAGE...
  • Page 40 COOLING PERFORMANCE DATA DSXC160241A*-LOW STAGE...
  • Page 41 COOLING PERFORMANCE DATA DSXC160241A*-LOW STAGE...
  • Page 42 COOLING PERFORMANCE DATA DSXC160241A*-HIGH STAGE...
  • Page 43 COOLING PERFORMANCE DATA DSXC160241A*-HIGH STAGE...
  • Page 44 COOLING PERFORMANCE DATA DSXC160361A*-LOW STAGE...
  • Page 45 COOLING PERFORMANCE DATA DSXC160361A*-LOW STAGE...
  • Page 46 COOLING PERFORMANCE DATA DSXC160361A*-HIGH STAGE...
  • Page 47 COOLING PERFORMANCE DATA DSXC160361A*-HIGH STAGE...
  • Page 48: Performance Data

    PERFORMANCE DATA ASXC160**1A* LOW STAGE *SXC160241A* / CA*F3636*6**+TXV / M BV C1200**-1** *SXC160361A* / CA*F3743*6**+TXV / MBVC1600**-1** Conditions : 80°F IDB, 67°F IWB @ 600 CFM , LOW STAGE Conditions: 80°F IDB, 67°F IWB @ 800 CFM, LOW STAGE Outdoor Total Se ns ible Late nt...
  • Page 49 PERFORMANCE DATA ASXC160**1A* HIGH STAGE *SXC160241A* / CA*F3636*6**+TXV / MBVC1200**-1** *SXC160361A* / CA*F3743*6**+TXV / MBVC1600**-1** Conditions: 80°F IDB, 67°F IWB @ 1200 CFM, High Stage Conditions: 80°F IDB, 67°F IW B @ 800 CFM, High Stage Outdoor Total Se ns ible Late nt Total Outdoor...
  • Page 50 PERFORMANCE DATA ASXC160[24-60]1B* LOW STAGE *SXC160361B* / CA*F3743*6**+TXV + MBVC1600**-1** *SXC160241B* / CA*F3636*6**+T XV +M BV C1200**-1* Conditions: 80°F IDB, 67°F IWB @ 800 CFM, LOW STAGE Conditions : 80°F IDB, 67°F IWB @ 540 CFM , L OW STAGE Outdoor Total Sensible...
  • Page 51 PERFORMANCE DATA ASXC160[24-60]1B* HIGH STAGE *SXC160361B* / CA*F3743*6** +TXV + MBVC1600**-1 *SXC160241B* / CA*F3636*6**+TXV+MBVC1200**-1* Conditions: 80°F IDB, 67°F IWB @ 1200 CFM, High Stage Conditions: 80°F IDB, 67°F IWB @ 780 CFM, High Stage Outdoor Total Sensible Latent Total Outdoor Total Sensible Latent...
  • Page 52 PERFORMANCE DATA DSXC160[24-60]1A* LOW STAGE *SXC160241A* / CA*F3636*6**+TXV+MBVC1200**-1* *SXC160361A* / CA*F3743*6***+TXV + MBVC1600**-1** Conditions: 80°F IDB, 67°F IWB @ 540 CFM, LOW STAGE Conditions: 80°F IDB, 67°F IWB @ 800 CFM, LOW STAGE Outdoor Total Sensible Latent Total Outdoor Total Sensible Latent Total...
  • Page 53 PERFORMANCE DATA DSXC160[24-60]1A* HIGH STAGE DSXC160361A* / CA*F3743*6** +TXV + MBVC1600**-1 DSXC160241A* / CA*F3636*6**+TXV+MBVC1200**-1* Conditions: 80°F IDB, 67°F IWB @ 1200 CFM, High Stage Conditions: 80°F IDB, 67°F IWB @ 780 CFM, High Stage Outdoor Total Sensible Latent Total Outdoor Total Sensible Latent...
  • Page 54 PERFORMANCE DATA DSXC160[48-60]1B* LOW STAGE DSXC160601B* / CA*F496*6**+TXV / M BV C2000**-1 ** DSXC160481A* / CA*F4961*6** +TXV / M BV C2000**-1B* Conditions : 80°F IDB, 67°F IWB @ 1400 CFM , LOW STAGE Conditions : 80°F IDB, 67°F IWB @ 950 CFM , LOW STAGE Outdoor Total Se ns ible...
  • Page 55 WIRING DIAGRAMS *SXC160[24-60]1A*/B* HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
  • Page 56 WIRING DIAGRAMS *SXC160[24-60]1A*/B* HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.