Appendix B: System Specifications
UPER
ERVER 1018R-WR User's Manual
Notes
System Cooling
Four sets of 4-cm counter-rotating cooling fans with an option for two more (fan
speed controlled by IPMI)
System Input Requirements
AC Input: 100-240 V, 50-60 Hz, 6-3 Amps
Power Supply
Rated Output Power: Dual hot-swap 400 W (Part# PWS-406P-1R)
Rated DC Output Voltages: +12V (33A), +5Vsb (3A)
With power distributor: +5V (25A), +3.3V (25A), -12V (0.6 A)
Operating Environment
Operating Temperature: 10º to 35º C (50º to 95º F)
Non-operating Temperature: -40º to 60º C (-40º to 140º F)
Operating Relative Humidity: 8% to 90% (non-condensing)
Non-operating Relative Humidity: 5% to 95% (non-condensing)
Regulatory Compliance
Electromagnetic Emissions: FCC Class A, EN 55022 Class A, EN 61000-3-2/-3-
3, CISPR 22 Class A
Electromagnetic Immunity: EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3,
EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11)
Safety: CSA/EN/IEC/UL 60950-1 Compliant, UL or CSA Listed (USA and
Canada), CE Marking (Europe)
California Best Management Practices Regulations for Perchlorate Materials:
This Perchlorate warning applies only to products containing CR (Manganese
Dioxide) Lithium coin cells. "Perchlorate Material-special handling may apply. See
www.dtsc.ca.gov/hazardouswaste/perchlorate"