(4) Replacing the Oscillator Circuit Boards

Figure 3.6 shows how to replace the oscillator circuit boards.
Figure 3.6 Replacing the oscillator circuit boards
When Removing and Closing the Upper Cover:
• Always shut OFF power when removing the upper cover or setting the switches.
(1) Remove the four screws of both sides of this
product and lift off the upper cover.
(2) Unscrew the screw connecting the oscillator
circuit board.
(3) Lift off the oscillator circuit board.
(4) Attach the J1 connector of another oscillator
circuit board for replacement to the connector
of this product.
(5) Secure the oscillator circuit board with the
screw, and replace the upper cover and secure
the four screws.
CAUTION
( 26 / 52 )