Downloading Firmware; Self-Check - Renesas Emulation Pod M30100T3-RPD-E User Manual

Emulation pod for m16c/10 series mcus
Table of Contents

Advertisement

(3) Downloading Firmware

If you have purchased this emulation pod newly, it is necessary to download the firmware. The
download procedure is given in Figure 2.2.
Before attempting to download the firmware, check the emulator debugger is installed and the
emulator is connected to the host machine. For more information, see each user's manual of the
emulator debugger and the PC4701.
Connect the PC4701 and this product and pod probe.
Within 2 seconds of turning the power ON, press the
RESET button of the PC4701 and check the maintenance
mode is accessed.
Download the firmware using the emulator debugger.
Quit the emulator debugger and shut down the PC4701.
Figure 2.2 Firmware download procedure when using the emulator for the first time

(4) Self-check

To confirm that your emulation pod works properly, execute the self-check after downloading the
firmware. The self-check procedure is given in Figure 2.3.
Within 2 seconds of turning the power ON, press the
system reset switch of the PC4701 and check it is in
maintenance mode.
Push the system reset switch of the PC4701 again to start
the self-check.
After about 40 seconds, check that the self-check is
complete normally and shut off the PC4701.
Figure 2.3 Self-check procedure
( 19 / 52 )
See "3.4 Connecting the PC4701
and Emulation Pod" (page 27) and
"3.5 Connecting the Pod Probe"
(page 29).
See "4.2 Downloading Firmware"
(page 34).
See "4.3 Self-check" (page 35).