2.4 When Using the Emulator for the First Time

(1) Making the MCU File

It is necessary to make an MCU file to use this product with the emulator debugger M3T-PD30.
According to the MCU you use, change the contents of the MCU file. Make the MCU file following
the description below using a text editor and store it in the "mcufiles" folder in the directory where
the emulator debugger is installed.
The MCU file contains information such as, SFR area, internal RAM area, internal ROM area,
firmware file name. The contents of the MCU file when using the M16C/1N Group (3KB RAM,
64KB ROM) are as follows:
Note that the seventh line is "M30620B" for M30100T-RPD-E but "M30620P" for M30100T3-RPD-E.

(2) Setting the Work Area

With this product, the emulator uses 32 bytes as a work area in emulation memory. Set the work area
address at 8000h.
The area used as a work area (32 bytes) is specified in the F/W and Work Area tab of the INIT dialog
box of the emulator debugger M3T-PD30. And set the work area as MAP=INT.
0
: SFR area
3FF
:
400
: Internal RAM
FFF
:
F0000
: Internal ROM
FFFFF
:
M30620P
: Name of firmware (Do not change.)
0
: Expansion No. M3T-PD30 V.4.00 or later required (Do not change.)
Start address
End address
Start address
End address
Start address
End address