Section 4 Verifying Operation - Renesas H8/3937 Series User Manual

H8/3937r, h8/3937 series tfp-100g user system interface cable (hs3937ecn61h) for e6000 emulator
Table of Contents

Advertisement

1. When using the H8/300L series E6000 emulator (HS388REPI60H), turn on the emulator
according to the procedures described in the H8/300L Series E6000 Emulator User's Manual
(HS388REPI60HE).
2. Verify the user system interface cable connections by accessing ports and checking the bus
states of the pins. If an error is detected, recheck the soldered IC socket and the location of
pin 1.
3. System Clock (OSC2, 1)
When the system clock is selected in the HDI Configuration Window and jumper P4 is set in the
user system interface cable, the system clocks in table 2 can be selected (see figures 10
and 11).
Table 2
Setting System Clocks
Configuration Window
2 MHz
Target/2
4. Subclock (DX2, 1)
When the switch is set on the expansion I/O board (Subclock selection) and jumper P5 is set on
the user system interface cable, subclocks in table 3 can be selected. Select target subclock in
the Configuration window (see figures 10 and 11).
Table 3
Setting Subclocks
Expansion I/O Board
(Subclock selection)
160 kHz
76.8 kHz
The setting of the subclock
selection switch can be either
160 kHz or 76.8 kHz.

Section 4 Verifying Operation

User System Interface Cable (P4)
For the setting of P4, either pins 1-2
or 2-3 can be connected.
1-2 connected
2-3 connected
User System Interface Cable (P5)
1-2 connected
2-3 connected
System Clock (∅)
2 MHz
5 MHz
Target clock/2
Subclock (f
)
W
160 kHz
76.8 kHz
Target subclock
15