Section 4 Verifying Operation - Renesas FP-144 User Manual

User system interface cable for e6000 emulator
Table of Contents

Advertisement

1. When using the E6000 emulator for the H8S/2633 series, turn on the emulator according to the
procedures described in the H8S Series E6000 Emulator User's Manual (HS2000EPI61HE).
2. Verify the user system interface cable connections by accessing the external memory and ports
to check the bus states of the pins with the MEMORY_FILL command (emulator command). If
an error is detected, recheck the soldered IC socket and the location of pin 1.
3. The emulator connected to this user system interface cable supports two kinds of clock sources
as the MCU clock: an emulator internal clock and an external clock on the user system. For
details, refer to the Emulator Supplementary Information (HS2633EPI61HE).
 To use the emulator internal clock
Select the clock in the emulator station as the system clock (φ), by using the CLOCK
command (emulator command).
 To use the external clock on the user system
Select the target clock Target or Target/2 with the CLOCK command (emulator command).
Supply the external clock from the user system to the emulator by inputting the external
clock from the EXTAL terminal on the cable head or connecting a crystal oscillator to the
EXTAL and XTAL terminals, and the subclock from OSC1 and OSC2. For details, refer to
the Clock Pulse Generator section, in the H8S/2643 Series Hardware Manual.
Figure 10 shows the oscillator circuit on the user system interface cable.
R1 1 M
HCU04 HCU04
HCU04
R2 270
EXTAL
XTAL
System clock oscillator circuit

Section 4 Verifying Operation

HCU04
To E6000
emulator
OSC1
Figure 10 Oscillator Circuit
R13 10 k
R5 3.3 M
R12 2.2 k
HCU04
HCU04
R6 470 k
OSC2
Subclock oscillator circuit
To E6000
emulator
HCU04
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

H8s/2643 seriesHs2643ech61h

Table of Contents