Renesas FP-100A User Manual page 20

User system interface cable for e6000 emulator
Table of Contents

Advertisement

Figure 9 shows the system clock oscillator on the user system interface cable and the subclock input
specifications.
R1 1 M
HCU04
To E6000
emulator
HCU04
R2 270
OSC1
OSC2
System clock oscillator
Figure 9 System Clock Oscillator and Subclock Input Specifications
4. Select the MCU type by setting the MCU type switch (SW1) as follows before using the user
system interface cable:
 For the H8/3834 series or H8/3814 series: Turn off the switch (to the 3834 side)
 For the H8/3877 series: Turn on the switch (to the 3876 side).
Figure 10 shows the allowable SW1 setting. Do not use any other setting.
3834
OFF
H8/3834series,
H8/3814 series
14
Vcc
0.8 Vcc
0.3 Vcc
0 V
SW1
3876
ON
Figure 10 SW1 Setting
55 ns max.
55 ns max.
Vcc: User System Vcc
Subclock input specifications
SW1
3834
3876
OFF
ON
H8/3877 series
0.8 Vcc
0.3 Vcc
(3.0 V to 5.0 V)