Modbus RTU RS-485

6.11 Display settings

6.
Modbus holding registers
MAG 6000
Modbus
Modbus
register
address
4:02901
2900
4:02902
2901
4:02903
2902
4:02904
2903
4:02907
2906
4:02908
2907
4:02913
2912
4:02914
2913
4:02915
2914
4:02916
2915
SFIDK.PS.023.D2.02
No. of
Data
Description
bytes
type
2
Byte
Language:
0 = English
1 = Deutsch
2 = Français
3 = Dansk
4 = Svenska
5 = Suomeksi
6 = Russian
7 = Español
8 = Italiano
9 = Português
10 = Polski
2
Byte
Display line 1:
0 = Volumeflow
1 = Totalizer 1
2 = Totalizer 2
2
Byte
Display line 2:
0 = Text for line 3
1 = Volumeflow
2 = Volumeflow %
3 = Q max.
4 = Totalizer 1
5 = Totalizer 2
6 = Batch cycle counter
7 = Sensor size
8 = Sensor type
9 = TAG number
10 = Operating time
11 = Q max. text
2
Byte
Display line 3:
0 = Volumeflow
1 = Volumeflow %
2 = Q max.
3 = Totalizer 1
4 = Totalizer 2
5 = Batch cycle counter
6 = Sensor size
7 = Sensor type
8 = TAG number
9 = Operating time
10 = Q max. text
2
Byte
Volumeflow unit
2
Byte
Volumeflow point
2
Byte
Totalizer 1 unit
2
Byte
Totalizer 1 point
2
Byte
Totalizer 2 unit
2
Byte
Totalizer 2 point
Read/
write
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W