Picture Tube Removal - Sony TRINITRON CPD-E210 Service Manual

Color monitor d99c chassis
Hide thumbs Also See for TRINITRON CPD-E210:
Table of Contents

Advertisement

2-4. PICTURE TUBE REMOVAL

WARNING: High voltage remains in the CRT even after the power is disconnected. To avoid electric shock, discharge CRT
before attempting to remove the anode cap. Short between anode and CRT coated earth ground strap.
NOTE:
After removing the anode, short circuit the anode of the picture tube and the anode cap to either the metal
chassis, CRT shield, or carbon painted on the CRT.
REMOVAL PROCEDURES
1 Turn up one side of the rubber cap in
the direction indicated by arrow a .
HOW TO HANDLE AN ANODE CAP
1 Do not use sharp objects which may cause damage to the
surface of the anode cap.
2 Do not squeeze the rubber covering too hard to avoid damag-
ing the anode cap. A material fitting called a shatter-hook ter-
minal is built into the rubber.
3 Do not force turn the foot of the rubber cover. This may cause
the shatter-hook terminal to protrude and damage the rubber.
ANODE CAP REMOVAL
2 Use your thumb to pull the rubber
cap firmly in the direction indicated
by arrow b .
— 13 —
3 When one side of the rubber cap
separates from the anode button,
the anode cap can be removed by
turning the rubber cap and pulling
it in the direction of arrow c .
CPD-E210

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents