1. Introduction

Thank you for purchasing the PROFIBUS-DP option "PDP003Z" for the VF-MB1. Before
using the PROFIBUS-DP option, please familiarize yourself with the product and be sure
to thoroughly read the instructions and precautions contained in this manual.
In addition, please make sure that this manual and "Installation Manual" is delivered to
the end user, and keep this function manual in a safe place for future reference or
drive/interface inspection.
This manual describes the supported functions for the "PDP003Z".
In conjunction with this manual, the following manuals are supplied by Toshiba, and they
are essential both for ensuring a safe, reliable system installation as well as for realizing
the full potential of the "PDP003Z":
- TOSVERT VF-MB1 Instruction Manual................................................E6581697
- VF-MB1 Option Installation Manual......................................................E6581739
Handling in general
Do not connect or disconnect a network cable while the drive power is on.
It may lead to electric shocks or fire.
See Installation manual attached with the option unit for cautions the handling.
Mandatory
Otherwise, it may lead to electric shocks, fire, injuries or damage to product.
Network control
Do not send the value out of the valid range to network variables.
Otherwise, the motor may suddenly start/stop and that may result in injuries.
Prohibited
Use an additional safety device with your system to prevent a serious accident due to the
network malfunctions. Usage without an additional safety device may cause an accident.
Mandatory
Set up "Communication error trip function (see below)" to stop Drive when the network
is deactivated by an unusual event such as tripping, an operating error, power outage,
failure, etc.
- PROFIBUS communication timeout (
- Drive operation at the communications loss action (
- Preset speed operation selection (
- Communication time-out condition selection (
Mandatory
Deactivated Drive may cause an accident, if the "Communication error trip function" is
not properly set up.
Make sure that the operation signals are STOP before resetting Drive's fault. The motor
may suddenly start and that may result in injuries.
Notes on operation
When the control power is shut off by the instantaneous power failure, communication
will be unavailable for a while.
The Life of EEPROM is approximately 100,000 times. Avoid writing a command more
than 100,000 times to the same parameter of the drive and the communication board.