Displaying Syslog Messages For Temperature; Changing Temperature Warning And Shutdown Levels - IBM 4002-Y2A Installation And User Manual

Ibm y-series of ethernet switches
Table of Contents

Advertisement

Displaying Syslog messages for temperature

The software sends a Syslog message and an SNMP trap if the temperature crosses
the warning or shutdown thresholds. The following methods describe how to view
the system log on the device. If you have configured the device to use a Syslog
server or SNMP trap receiver, see the documentation for the server or receiver.
To display the system log, enter the show log command at any CLI level.
FCX648SHPOE Switch# show log
Syslog logging: enabled (0 messages dropped, 0 flushes, 0 overruns)
Buffer logging: level ACDMEINW, 8 messages logged
level code: A=alert C=critical D=debugging M=emergency E=error
I=informational N=notification W=warning
Static Log Buffer:
Dynamic Log Buffer (50 entries):
at 0 days 0 hours 2 minutes 0 seconds, level alert
Temperature 48.0 C degrees, warning level 45.0 C degrees, shutdown level 55.0 C
degrees
at 0 days 0 hours 1 minutes 0 seconds, level alert
Temperature 40.0 C degrees, warning level 35.0 C degrees, shutdown level 45.0 C
degrees

Changing temperature warning and shutdown levels

The default warning temperatures and the default shutdown temperatures for the
device are:
- Warning temperature is 85° C (measured on mainboard)
- Shutdown temperature is 90° C (measured on mainboard)
Note: These temperatures reflect the temperature of the board inside the device.
To change the temperature at which the device sends a warning, enter a command
similar to the following at the Privileged EXEC level of the CLI:
FCX624 Router# temperature warning 1 85
Syntax: temperature warning <stack-unit> <value>
<stack-unit> can be 1 - 8.
<value> can be 0 - 125
To display the current temperature readings, enter the temp command as shown.
FCX624S Switch# temperature
FCX624S Switch# temperature warning
FCX624S Switch# temperature warning
FCX624S Switch# temperature warning 1 87
FCX624S Switch# show chassis
The stack unit 1 chassis info:
Power supply 1 (NA - AC - Regular) present, status ok
Power supply 2 not present
Fan ok, speed (auto): [[1]]<->2<->3
Fan speed switching temperature thresholds:
44
Ethernet y-series Installation and User Guide: Installation and User Guide
temperature
temperature sensor commands
warning
Temperature at which the module sends a warning
DECIMAL
Stack Number
1 -> 2 @ 61 deg-C
1 <- 2 @ 56 deg-C