13. Value of OFF command frame sent to 2nd association group
The value of 0 turns OFF the device, 255 turns it On. In case of asso-
ciating the Dimmer or Roller Shutter module, values 1-99 allow to set
an associated device to a specified level.
Available settings: 0-99 or 255
Default setting:
14. Time delay of ON command frame
Time period after which On command frame will be sent.
Available settings: 0-32400 - time in seconds
Default setting:
15. Time delay of OFF command frame
Time period after which OFF command frame will be sent.
Available settings: 0-32400 - time in seconds
Default setting:
20. Type of sent alarm frames
Type of control frames transmitted to the main controller and 3rd as-
sociation group "Alarm". If an external sensor is connected to In input,
it is possible to choose its functionality. Otherwise it is recommended
to set this parameter to default value.
Available settings: 0 - Door/Window Sensor (General Purpose Alarm)
Default setting:
30. Delay of tamper alarm cancellation
Time period after which a tamper alarm will be cancelled.
Available settings: 0-32400 - time in seconds
Default setting:
31. Reporting tamper alarm cancellation
Reporting cancellation of tamper alarm to the controller and 5th as-
sociation group.
Available settings: 0 - do not send tamper cancellation report
Default setting:
0
Parameter size:
0
Parameter size:
0
Parameter size:
1 - smoke sensor (Smoke Alarm)
2 - CO detector (CO Alarm)
3 - CO2 detector (CO2 Alarm)
4 - high temperature sensor (heat Alarm)
5 - flood sensor (Water Alarm)
0
Parameter size:
5
Parameter size:
1 - send tamper cancellation report
1
Parameter size:
2 [bytes]
2 [bytes]
2 [bytes]
1 [byte]
2 [bytes]
1 [byte]
ADVAnCED PARAMETERS
15
!
CAUTION
In order to activate
new settings of pa-
rameter 20, it is re-
quired to remove and
re-add the device to
the main Z-Wave con-
troller. This parameter
is not reset during re-
moval process.