Base Station Reciter
Gateway Module
12
Description
The reciter module comprises the
receiver, exciter and digital control
circuitry. It also incorporates the
network board, which provides the
Ethernet interface, the analog line
interface, and general purpose digital
inputs and outputs.
Reciters are installed in the subrack
from right to left (viewed from the
front), with the right-hand position
corresponding to position 1 on the
control panel. Only the reciter in
position 1 can communicate with the PMU (if fitted).
It is not possible to convert a reciter to a gateway module.
The gateway module of the P25 Console Gateway appears identical to a
base station reciter. However, they are electronically distinct. The P25
Console Gateway has no RF capability. It performs P25 encryption and
decryption at the analog line, which the base station is incapable of.
Gateway modules are installed in the subrack from right to left (viewed from
the front), with the right-hand position corresponding to position 1 on the
control panel. Only the gateway module in position 1 can communicate
with the PMU (if fitted).
It is not possible to convert a gateway module into a reciter.
TB9100/P25 CG Installation and Operation Manual
© Tait Electronics Limited January 2007