Front panel LEDs

Item
Description
UID LED
1
System health LED*
2
Drive fault LED
3
Drive activity LED
4
Drawer temp LED
5
* The system health LED flashes amber when the storage blade establishes a connection with the enclosure, either
immediately after installation or when the storage blade is removed and reinstalled. If the LED continues to flash for more
than 2 minutes, there is a fault. Make sure the partner server blade is powered down before the storage blade is installed.
Status
Blue = Identified
Off = Not identified
Green = Normal operation
Flashing amber = No partner blade, or
not yet recognized
Solid amber = Degraded condition
Flashing red = System critical
Red = Drive over-temperature triggered
shutdown
Off = Normal operation
Solid amber = Drive failed
Flashing amber = Predictive failure
Solid green = Drive installed
Flashing green = Drive activity
established
Flashing green (slow) = Drive rebuilding
Off = Drawer is closed, or thermal
shutdown has occurred.
Flashing amber (1 per 5 seconds) =
Drawer is open.
Flashing amber (2 per second) = Drives
have reached near-critical temperatures.
Component identification 45