Drive - HP StorageWorks D2200sb Maintenance And Service Manual

Pcie storage blade
Hide thumbs Also See for StorageWorks D2200sb:
Table of Contents

Advertisement

Remove the drive blank.
2.
To replace the component, reverse the removal procedure.

Drive

WARNING:
internal system components to cool before touching them.
CAUTION:
before beginning any installation procedure. Improper grounding can cause ESD.
CAUTION:
or the enclosure unless the first drive bay is populated with a drive, and drive bays 2 and 3 and
all device bays are populated with either a component or a blank.
CAUTION:
temperature alarm is triggered under the following conditions:
A slow beep and flash (1 every 5 seconds) indicate that the drive drawer is open. The drives
are not fully protected by system air flow.
A fast beep and flash (2 per second)—To avoid drive damage or data loss and storage blade
shutdown, close the drive drawer immediately.
When the drives reach critical temperatures, the system shuts down.
To remove the component:
Determine the status of the drive from the hot-plug SAS or SATA drive LED combinations
1.
SATA drive LED
Back up all server data.
2.
To reduce the risk of personal injury from hot surfaces, allow the drives and the
To prevent damage to electrical components, properly ground the storage blade
To prevent improper cooling and thermal damage, do not operate the storage blade
Thermal regulation is maintained only when the drive drawer is closed. The drive
combinations" on page 46).
Removal and replacement procedures 28
("SAS and