To remove the component:
Back up all data on the storage blade.
1.
Power down the partner server blade (on page 22).
2.
Remove the storage blade (on page 22).
3.
Remove the access panel (on page 26).
4.
Disconnect the FBWC capacitor pack cable from the system board, and then remove the component.
5.
To replace the component, reverse the removal procedure.

FBWC module

WARNING:
internal system components to cool before touching them.
CAUTION:
before beginning any installation procedure. Improper grounding can cause ESD.
CAUTION:
the storage blade in this manner results in improper airflow and improper cooling that can lead
to thermal damage.
To remove the component:
Back up all data on the storage blade.
1.
Power down the partner server blade (on page 22).
2.
Remove the storage blade (on page 22).
3.
Remove the access panel (on page 26).
4.
To reduce the risk of personal injury from hot surfaces, allow the drives and the
To prevent damage to electrical components, properly ground the server blade
Do not operate the storage blade with the access panel open or removed. Operating
Removal and replacement procedures 30