Drawings For 2-Section Group - Danfoss PVG 32 Technical Information

Proportional valve group ag modules
Hide thumbs Also See for PVG 32:
Table of Contents

Advertisement

Technical Information
Dimensions and schematic examples

Drawings for 2-section group

32
PVG 32 AG Modules
Drawing for 3-section valve group
View
X-X
F
H
G
N
37,5
38,5
F: Port T2; M14 x 1.5
G: Port T0; M14 x 1.5
H: Port LS; M14 x 1.5
I: Port T02; M14 x 1.5
J: PVB A and B port; M22 x 1.5
PVG 32: 2 section valve group, typical example for Loader application for tractors.
To be supplied with fixed pump.
The PVP inlet has HPCO feature, consequently the PVT has tank port.
PVED-CC with APM-JPT connector.
11051935 • Rev AE • Feb 2014
95
I
J
68
62
276
L
M
K: Fixing holes; M8 x min. 10
L: PVBZ-HS work port B and T; M22 x 1.5
M: Port P and T; M27 x 2.0
N: Port P2; M14 x 1.5
K
P301 078