Installation; Location Of Ice Machine - Manitowoc UDE065A Technician's Handbook

Neo series undercounter ice machines
Table of Contents

Advertisement

Location of Ice Machine

The location selected for the ice machine must meet the
following criteria. If any of these criteria are not met,
select another location.
The location must be indoors.
The location must be free of airborne and other
contaminants.
Air temperature: Must be at least 50°F (10°C) but must
not exceed 113°F (43.4°C).
UDE065 & UDE080: Must be at least 40°F (4°C) but
must not exceed 110°F (45°C)
The location must not be near heat-generating
equipment or in direct sunlight.
The location must be capable of supporting the weight
of the ice machine and a full bin of ice.
The location must allow enough clearance for water,
drain, and electrical connections in the rear of the ice
machine.
The location must not obstruct airflow through or
around the ice machine (condenser airflow is in and
out the front). Refer to the chart below for clearance
requirements.
The ice machine must be protected if it will be
subjected to temperatures below 32°F (0°C). Failure
caused by exposure to freezing temperatures is not
covered by the warranty.
Part Number 000014797 Rev02 05/18

Installation

21

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents