Cleaning and Sanitizing Procedure UDE080

Ice machine cleaner is used to remove lime scale and
mineral deposits. Ice machine sanitizer disinfects and
removes algae and slime.
Move the toggle switch to Off after ice falls
Step 1
from the evaporator at the end of a Harvest cycle. Or, set
the toggle switch to Off and allow the ice to melt off the
evaporator.
Never use anything to force ice from the evaporator.
Damage may result.
Remove all ice from the bin.
Step 2
Wear rubber gloves and safety goggles (and/or face
shield) when handling Ice Machine Cleaner or Sanitizer.
Do not mix Ice Machine Cleaner and Sanitizer solutions
together. It is a violation of Federal law to use these
solutions in a manner inconsistent with their labeling.
To start a cleaning cycle move the toggle switch
Step 3
to Wash.
Wait until water flows over the evaporator
Step 4
(about three minutes) then add the proper amount of
Manitowoc Ice Machine Cleaner to the water trough.
Model
UDE080
52
Caution
,
Warning
n
Caution
,
Part Number 000014797 Rev02 05/18
Amount of Cleaner
1.5 ounces (45 ml)