Control Board Test Mode; Operating Ice Machine With Bin And Touch Pad; Removed - Manitowoc UDE065A Technician's Handbook

Neo series undercounter ice machines
Table of Contents

Advertisement

CONTROL BOARD TEST MODE

NOTE: The ice damper/bin switch can be open or closed
and does not effect the operation of the test mode.
To enter the test mode press and hold the test switch on
the control board for 3 seconds. Refer to "UF0310 Wiring
Diagram 1Ph Air/Water
Self Contained Air & Water-cooled" on page 241. The
control board test mode performs the following functions
for a 2 minute time period:
Energizes all control board relays
Energizes all control board lights
Energizes all touch pad control lights
After 2 minutes the control board will automatically
initiate and complete one ice making cycle, then stop.
Canceling a test cycle:
To cancel a test cycle press the test button a second time.
Restarting a test cycle:
The test cycle will restart each time the test button is
pressed for a 3 second time period.

OPERATING ICE MACHINE WITH BIN AND TOUCH PAD

REMOVED

The ice machine is designed to allow diagnostic procedures
to be performed with the bin removed. The touch pad is
attached to the bin and is disconnected during the removal
process. Use the control board test mode to operate the
ice machine without connecting the touch pad. Refer to
"UF0310 Wiring Diagram 1Ph Air/Water
Self Contained Air & Water-cooled" on page 241
NOTE: Software versions before 2.70 operate for 1 cycle
in test mode. Software versions after 2.70 operate for 500
cycles in test mode.
92
Part Number 000014797 Rev02 05/18