Component Check Procedures; Main Fuse - Manitowoc UDE065A Technician's Handbook

Neo series undercounter ice machines
Table of Contents

Advertisement

Component Check Procedures

MAIN FUSE

Function
The control board fuse stops ice machine operation if
electrical components fail causing high amp draw.
Specifications
UDE080/U0140/UF0140/U0190/UF0190/U240/UF240/
U310/UF310 - 250 Volt, 10 amp.
UDE065 - 250 Volt 8 amp
High (line) voltage is applied to the control board at
all times. Removing the control board fuse or pressing
the power button will not remove the power supplied
to the control board.
Check Procedure
1. If the curtain light is on with the ice damper closed,
the fuse is good.
Disconnect electrical power to the entire ice machine
before proceeding.
2. Remove the fuse. Check the resistance across the fuse
with an ohmmeter.
Reading
Open (OL)
Closed (O)
Part Number 000014797 Rev02 05/18
Warning
n
Warning
n
Result
Replace fuse
Fuse is good
183