I/O Signal When Cc-Link Ver.2 Double Setting Is Selected (Pr. 544 = "12") - Mitsubishi Electric FR-A7NC E kit-SC Instruction Manual

700 series cc-link communication function
Hide thumbs Also See for FR-A7NC E kit-SC:
Table of Contents

Advertisement

6.2.3

I/O signal when CC-Link ver.2 double setting is selected (Pr. 544 = "12")

(1) Remote I/O (32 points)
Same as when Pr. 544 =
(2) Remote register
Description
Address
Upper 8 Bits
RWwn
Monitor code 2
RWwn+1
Set frequency (0.01Hz increments)
Link parameter
RWwn+2
extended setting
RWwn+3
RWwn+4
Monitor code 3
RWwn+5
Monitor code 4
RWwn+6
Monitor code 5
RWwn+7
Monitor code 6
("n" indicates a value determined according to the station number setting.)
* When Pr. 37 is not equal to "0", this will be machine speed display (1 increments).
0
(Refer to page 43)
"
"
Refer
Lower 8 Bits
Page
Monitor code 1
*
Instruction code
Write data
to
Address
Upper 8 Bits
55
RWrn
RWrn+1
55
56
RWrn+2
Reply code 2
56
RWrn+3
56
RWrn+4
56
RWrn+5
56
RWrn+6
RWrn+7
56
I/O SIGNAL LIST
Description
Lower 8 Bits
First monitor value
Second monitor value
Reply code 1
Read data
Third monitor value
Fourth monitor value
Fifth monitor value
Sixth monitor value
Refer
to
Page
58
58
58
58
59
59
59
59
6
47

Advertisement

Table of Contents
loading

Table of Contents