Mitsubishi Electric FR-A7NC E kit-SC Instruction Manual page 70

700 series cc-link communication function
Hide thumbs Also See for FR-A7NC E kit-SC:
Table of Contents

Advertisement

Item
Parameter
Faults history batch clear
All parameter clear
*4
Turning OFF the power supply while clearing parameters with H5A5A or H55AA also clears the communication parameter
settings back to the initial settings.
DETAILS OF INPUT AND OUTPUT SIGNALS
Read /
Code
Write
Number
 Refer to the instruction code in the parameter list in the inverter
H0000 to
manual to read and write as required.
Read
H0063
Write to Pr. 77 and Pr. 79 is disabled.
When setting Pr.100 and later, set link parameter extended setting.
 Set 65520 (HFFF0) as a parameter value "8888" and 65535
H0080 to
(HFFFF) as "9999".
Write
H00E3
 When changing the parameter values frequently, set "1" in Pr. 342
to write them to the RAM. (Refer to page 28.)
Write
H00F4
H9696: Clears the faults history in batch.
All parameters return to the initial values.
Whether to clear communication parameters or not can be selected
according to data. (: Clear, : Not clear)
Refer to the inverter manual for parameter clear, all clear, and
communication parameters.
Write
H00FC
All parameter clear
When clear is executed for H9696 or H9966, communication-related
parameter settings also return to the initial values. When resuming
operation, set the parameters again.
Executing clear will clear the instruction code H00EC, H00F3, and
H00FF settings.
Description
Clear Type
Data
H9696
Parameter clear
H5A5A
H9966
H55AA
Communication Pr.
*4
*4
63
7