Disassembly Procedures
WARNING

Magnetron

Magnetron is located on the side of the cavity.
1. Disconnect power to oven and remove outer case,
(see "Outer Case" section).
2. Discharge high voltage capacitor, (see page 16
capacitor testing procedures).
3. Remove blower motor assembly (see "Blower Motor"
procedure).
4. Remove terminal plug from filament terminals.
5. Remove screws securing magnetron cutout bracket
to magnetron.
6. Remove screws securing magnetron to the wave
guide.
7. Replace magnetron and reverse procedure to
reassemble.
NOTE: When replacing magnetron, make sure gasket is
in correct position and in good condition.
CAUT IO N
During replacement of magnetron, be certain the R.F.
anode gasket is in place around the anode stud.
WARNING
A microwave leakage test must be performed
anytime a magnetron assembly is removed, replaced,
disassembled, or adjusted for any reason.
©2010 ACP, Inc.
To avoid the risk of electrical shock, personal injury, or death,
disconnect power to oven and discharge the capacitors before
following any disassembly procedure.
Blower Motor
1. Disconnect power to oven and remove outercase,
2. Remove outer case.
3. Disconnect wiring from blower motor, fuse block and
4. Remove the two screws holding the blower motor
5. Remove the screw holding the blower motor bracket
6. Remove the upper screw holding the high voltage
7. Remove the lower screw holding the duct assembly.
Magnetron
Magnetron
16400007 Rev. 0
(see "Outer Case" procedure).
lower magnetron tco.
bracket to the upper plate.
to the back cover.
capacitor bracket.
H.V capacitor
bracket
H.V
Transformer
Blower Motor ASS'Y
Suction
Guide
H.V
Transformer