Door Assembly; Door Disassembly - ACP RFS12MPSB Service Manual

Commercial microwave oven
Table of Contents

Advertisement

Disassembly Procedures
WARNING
Door Removal
1. Disconnect power to oven.
2. Open oven door, remove top hinge cap, and slowly
lift door to disengage the hinge pins at top and
bottom.
3. To reinstall door, place top pin into slot first, then
align bottom pin.
4. Reinstall top hinge cap.

Door Disassembly

1. Disconnect power to oven.
2. Remove oven door, (see "Door Removal").
3. Begin at the bottom of the door near hinge, insert flat
blade screwdriver between choke cover and outer
door panel. Gently pry upward on choke cover to
release tabs. Work in clockwise direction to remove
choke cover.
22
To avoid the risk of electrical shock, personal injury, or death,
disconnect power to oven and discharge the capacitors before
following any disassembly procedure.
To avoid property damage, care must be taken when
prying choke cover from oven door.
4. Remove screw securing door handle to latch
assembly.
5. Slide latch assembly downward and pull away from
door frame to release.
6. Remove screws securing choke assembly to outer
door panel.
NOTE: When disassembling door, use caution to
prevent deformation of slats on door frame/
choke assembly.
7. Begin at hinge side of door near bottom, insert
flat blade screwdriver between door frame/choke
assembly and outer door panel. Gently pry outer
door panel away from door frame to release tabs.
Work in clockwise direction to remove door frame.
8. Remove spring from hinge assembly.
9. Remove screws securing hinge assembly to choke
assembly.
10. Reassemble in reverse order.
A microwave leakage test must be performed anytime
a door assembly is removed, replaced, disassembly,
or adjusted for any reason.
16400007 Rev. 0