Testing Procedures
To avoid risk of electrical shock, personal injury or death; disconnect power to oven and discharge capacitor
before servicing, unless testing requires power.
Illustration
Electronic Control
Keyboard assembly
RFS12SW2B
Electronic Control
Keyboard assembly
RFS12MPSB
18
!
Component
Continuity is indicated as
Ω
100
1
2
3
4
5
6
7
8
9
10
11
Continuity is indicated as
Ω
100
1
2
3
4
5
6
7
8
9
10
11
16400007 Rev.0
W ARNING
Testing
Pad
and below.
0
1
2
3
4
5
6
7
8
9
HOLD (0%)
DEFROST
(20%)
MEDIUM (50%)
MED-HI (70%)
TIME ENTRY
STOP/RESET
START
Pad
and below.
0
1
2
3
4
5
6
7
8
9
QTY 2X
HOLD (0%)
DEFROST
(20%)
MEDIUM (50%)
MED-HI (70%)
TIME ENTRY
STOP/RESET
START
Results
Trace
Measurement
1 & 8
Continuity
2 & 8
Continuity
3 & 8
Continuity
4 & 8
Continuity
5 & 8
Continuity
6 & 8
Continuity
7 & 8
Continuity
1& 9
Continuity
2 & 9
Continuity
3 & 8
Continuity
1 & 10
Continuity
2 & 10
Continuity
3 & 10
Continuity
4 & 10
Continuity
5 & 10
Continuity
6 & 10
Continuity
7 & 10
Continuity
Trace
Measurement
1 & 8
Continuity
2 & 8
Continuity
3 & 8
Continuity
4 & 8
Continuity
5 & 8
Continuity
6 & 8
Continuity
7 & 8
Continuity
1& 9
Continuity
2 & 9
Continuity
3 & 8
Continuity
7 & 9
Continuity
1 & 10
Continuity
2 & 10
Continuity
3 & 10
Continuity
4 & 10
Continuity
5 & 10
Continuity
6 & 10
Continuity
7 & 10
Continuity
©2010 ACP, Inc.