Microwave Leakage Test; Equipment; Procedure For Measuring Radiation Leakage; Measurement With The Outer Panel Removed - ACP RFS12MPSB Service Manual

Commercial microwave oven
Table of Contents

Advertisement

Microwave Leakage Test

To avoid risk of electrical shock, personal injury, or death, disconnect power to oven and discharge capacitor
before servicing, unless testing requires power.
!
Check for radiation leakage after servicing. Should
the leakage be more than 4 mW/cm
Inc. immediately. After repairing or replacing any
radiation safety device, keep a written record for
future reference, as required by D.H.H.S. and
HEW regulations. This requirement must be strictly
observed. In addition, the leakage reading must be
recorded on the service repair ticket while in the
customer's home.

Equipment

• Electromagnetic radiation monitor
• 600 cc glass beaker or plastic power bowl
Procedure for Measuring Radiation
Leakage
Note before measuring:
• Do not exceed meter full scale deflection. Leak
monitor should initially be set to the highest scale.
• To prevent false readings the test probe should be
held by the grip portion of the handle only.
• The scan speed is equal to one inch per antenna
revolution or one inch per second if antenna speed
is unknown.
• Areas to be checked are all door seal areas and
any venting parts.
• Leakage with the outer panel removed ...4mW/cm
or less.
• Leakage for fully assembled oven with door
normally closed ...4 mW/cm
• Leakage for a fully assembly oven (before the latch
switch (primary) is interrupted) while pulling the
door
... 4 mW/cm
or less.
2
1. Pour 275 cc ±15 cc (9 oz ±1/2 oz) of 20°C ± 5°C
(68°F ± 9°F) water in a beaker which is graduated
to 600 cc and place the beaker in the center of
oven.
2. Set the radiation monitor to 2450 MHz and use it
following the manufacturer's recommended test
procedure to assure correct results.
3. While measuring the leakage, always use the two
inch (5 cm) spacer supplied with the probe.
4. Press the start pad or turn on the timer and with
the magnetron oscillating, measure the leakage
by holding the probe perpendicular to the surface
being measured.
©2010 ACP, Inc.
!
WARNING
inform ACP,
2
2
or less.
16400007 Rev. 0
WARNING
Measurement with the Outer Panel
Removed
Avoid contacting any high voltage components.
Whenever you replace the magnetron, measure for
radiation leakage before the outer panel is installed
and after all necessary components are replaced or
adjusted. Special care should be taken in measuring
around the magnetron.
Measurement with a Fully Assembled
Oven
After all components including the outer panel are
fully assembled, measure for radiation leakage
around the door periphery, the door viewing window,
the exhaust opening, and air inlet openings.
Record Keeping and Notification After
Measurement
1. After any adjustment or repair to a microwave
oven, a leakage reading must be taken. Record
this leakage reading on the repair ticket even if it
is zero.
2. A copy of the repair ticket and the microwave
leakage reading should be kept by the repair
2
facility.
!
WARNING
15