ACP RFS12MPSB Service Manual page 10

Commercial microwave oven
Table of Contents

Advertisement

Troubleshooting Procedures
Trouble 1: The following visual conditions indicate a probable failed control circuit.
1. Incomplete segments.
• Segment missing.
• Partial segment missing.
• Digit flickering (Note: Slight flickering is normal.)
2. Colon does not turn on or blink.
3. A distinct change in the brightness of one or more numbers in display.
4. One or more digits in the display are not lighting.
5. Display indicates a number different from one touched, for example, key in 5 and 3 appears in the display.
6. Specific numbers (for example 7 or 9) will not display when key pad is touched.
7. Display does not count down with time blinking or up with clock operation.
8. Display obviously jumps in time while counting down.
9. Display counts down too fast while cooking.
10. Each indicator light does not turn on after setting cooking cycle.
11. Display time of day does not reappear when cooking is finished.
CONDITION
1. No input can be
programmed.
2. Some inputs
cannot be
programmed.
3. Display shows a
number or gure
di erent from one
touched.
4. Random
programming
when touching
other pads.
5. Display is xed
at some gure
and can not
accept any
input.
10
CHECK
Check the conn-
Continuity.
ection between
membrane key
assembly and
No continuity.
PCB assembly.
Everything works
Replace key
as speci ed.
membrane
assembly and
check operation.
Still have trouble.
16400007 Rev. 0
RESULT
CAUSE
Defective PCB
assembly.
Loose
connection.
Defective key
membrane
assembly.
Defective PCB
assembly.
REMEDY
Replace PCB
assembly.
Connect them
tightly.
Replace key
membrane
assembly.
Replace PCB
assembly.
©2010 ACP, Inc.