At the factory, the +5 V output is set between 5.OOV to 5. 10 V at
60% rated load, and the + 12 V Output is checked to be within the
accuracy range.
The adjustable range for the +5 V output is ± 5 %.
Note:
+12 V output voltage will track the adjustment.
Ripple and noise
The peak to peak ripple and noise for each output is less than 1%
of output voltage at rated load, which is measured by a 15 MHz
bandwidth limited oscilloscope and the each output is connected
with 0.47 uF capacitor.
Line regulation
The line regulation Is less than ±1% at rated load with ±10%
change In input voltage.
Load regulation
The load regulation for +5 V is less than ±1 %, for +12 V Is less
than ±10 %, which are measured by changing the output load from
20 % to 100 % of the rated load, and the other output is kept at
60 % rated load.
A.1.4 GENERAL FEATURES
Efficiency
The efficiency is higher than 70 % while measuring at nominal line
and rated load.
Hold up time
The hold up time is longer than 16 ms at 115 V
input and rated
AC
load.
Protection
Over voltage protection
Appendix A Power Supply Specifications