ABB WaterMaster FET100 User Manual page 30

Electromagnetic flowmeter transmitter
Table of Contents

Advertisement

WaterMaster FET100
Electromagnetic floweter | Transmitter
Temperature limitations
Ambient temperature
Remote transmitter
Integral transmitter
Temperature coefficient
Environmental protection
Humidity: 0 to 100 %
Rating: IP67 (NEMA 4X) to 1m (3.3 ft) depth
Tamper-Proof Security
Write access prevented by internal switch combined with
external security seals for MID applications
Languages
English, French, German, Italian, Spanish, Polish
Infrared service port
USB adapter (accessory), USB 1.1. and 2.0 compatible
Driver software for Windows 2000, XP, 7 (32-bit) and Vista
Housing material
Powder-coated aluminium with glass window
Hazardous approvals (HART variant only)
FM & FMc Class 1 Div 2
(FM listing NI / 1 / 2 / ABCD / T4, S / II, III / 2 / FG /T4,
Ta=60C; Type 4X, IP67 – for transmitter and integral mounting
Ta=70C, Type 6P, IP68 – for remote sensor type)
(FMc listing NI / 1 / 2 / ABCD / T4, DIP / II, III / 2 / FG /T4,
Ta=60C; Type 4X, IP67 – for transmitter and integral mounting
Ta=70C, Type 6P, IP68 – for remote sensor type)
FET, FEV, FEW and FEF DN700 to 2200 (27/28* to 84) only
*Size is dependent on flange specification
Declaration of Conformance
Copies of CE and PED certification will be available on request.
WaterMaster has OIMLR49 Certificate of Conformity to accuracy class 1 and 2 – copies of accuracy
certification are available on request.
WaterMaster has been type examined under directive MID 2004/22/EC, Annex MI-001 – copies of this
certificate are available on request.
28
–20 to 60 °C (–4 to 140 °F)
–20 to 60 °C (–4 to 140 °F)
Typically <±10 ppm/°C @ Vel 0.5 mls
5 Specification
DS/WM–EN Rev. J
OI/FET100–EN Rev. A