Installation Guide
IP-DECT Base Station & IP-DECT Gateway
Appendix A. RFP Power Consumption
The tables below show power consumption for a base station connected to and powered
from the IPBL.
The maximum cable length for base stations connected to the IPBL must not exceed 1500
meters.
A.1 KRCNB 201
Cable
length
(metres)
1000
1100
1200
1300
1400
1500
Table 1 Power consumption (watts) of base stations and cabling when powered from the IPBL.
15 October 2014 / Ver. B
0.4 mm
0.4 mm
wire size
wire size
()
()
Without
With
EPP
EPP
0
7.5
7.5
100
7.9
7.8
200
8.3
8.0
300
8.9
8.3
400
9.8
8.7
500
11.3
9.2
600
-
9.8
700
-
10.7
800
-
12.3
900
-
-
-
-
-
-
-
-
-
-
-
-
-
-
0.5 mm
0.5 mm
0.6 mm
wire size
wire size
wire size
()
()
()
Without
With
Without
EPP
EPP
EPP
7.5
7.5
7.5
7.8
7.7
7.7
8.0
7.8
7.8
8.3
8.0
8.0
8.7
8.2
8.2
9.2
8.5
8.4
9.8
8.7
8.6
10.7
9.0
8.8
12.3
9.4
9.1
-
9.8
9.5
-
10.3
9.9
-
11.1
10.4
-
12.3
11.1
-
-
12.1
-
-
-
-
-
-
TD 92989EN
0.6 mm
wire size
()
With
EPP
7.5
7.6
7.7
7.8
7.9
8.0
8.2
8.3
8.4
8.6
8.8
8.9
9.1
9.3
9.6
9.9
35