A.1 KRCNB 201
Cable
length
(metres)
1000
1100
1200
1300
1400
1500
Table 1 Power consumption (watts) of base stations and cabling when powered from the IPBL.
15 October 2014 / Ver. B
0.4 mm
0.4 mm
wire size
wire size
()
()
Without
With
EPP
EPP
0
7.5
7.5
100
7.9
7.8
200
8.3
8.0
300
8.9
8.3
400
9.8
8.7
500
11.3
9.2
600
-
9.8
700
-
10.7
800
-
12.3
900
-
-
-
-
-
-
-
-
-
-
-
-
-
-
0.5 mm
0.5 mm
0.6 mm
wire size
wire size
wire size
()
()
()
Without
With
Without
EPP
EPP
EPP
7.5
7.5
7.5
7.8
7.7
7.7
8.0
7.8
7.8
8.3
8.0
8.0
8.7
8.2
8.2
9.2
8.5
8.4
9.8
8.7
8.6
10.7
9.0
8.8
12.3
9.4
9.1
-
9.8
9.5
-
10.3
9.9
-
11.1
10.4
-
12.3
11.1
-
-
12.1
-
-
-
-
-
-
TD 92989EN
0.6 mm
wire size
()
With
EPP
7.5
7.6
7.7
7.8
7.9
8.0
8.2
8.3
8.4
8.6
8.8
8.9
9.1
9.3
9.6
9.9
35

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IP-DECT IPBS1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

This manual is also suitable for:

Ip-dect bs3x0Ip-dect ipbs2Ip-dect ipblIp-dect db1

Table of Contents