using the up/down arrows, and set the numerical values of the parameters
listed below.
- Configuration (1) [ 1 ]
Enter the zone number
Enter the "CONTROL UNITS" menu, the "LOGICS" submenu, and the
"SPECIAL LOGICS" submenu; then scroll the display screenfuls using the
up/down arrows, and set the numerical values of the parameters listed
below.
- Address (11 ) [ 0 ]
ON
activates closed loop
OFF open loop
- Address (12) [ 0 ]
ON
master
OFF no master.
11.2) Programming of centralised installation through display
The display programmer available in the board allows you to set all the
ALTAIR control panel functions. Make reference to fig. A and B. Set the
zone number in the PARAMETERS menu, and set the closed loop/open
loop and master/no master values in the LOGICS menu.
The predefined parameter is shown between square brackets [0].
The writing appearing on the display is indicated between round brackets.

12) SELF-DIAGNOSIS MENU (SELF-DIAGNOSIS)

In the SELF-DIAGNOSIS menu you can check the external connections: In
case of error, the display indicates the number of the terminal which does
not work correctly, therefore proceed to checking the devices connected.
Make reference to fig. A and B.
You can also carry out self-diagnosis through UNIPRO. In this case connect
the UNIPRO programmer to the control unit by means of the UNIDA
accessory (see fig. 4). The Altair control unit does not supply the UNIPRO
programmer, which therefore needs an appropriate supply unit.
Enter the "CONTROL UNITS" menu, the "SELF-DIAGNOSIS" submenu
and press ENTER. Wait for the command to be executed, after which you
get an "All OK!" reply if the external wiring is correct; otherwise, in case of
error, an error diagnosis is shown, as seen in fig. B.

13) STATISTICS

The statistics are only managed through UNIPRO. Therefore connect the
UNIPRO programmer to the control unit, enter the CONTROL UNITS/
STATISTICS menu and scroll the screenful displaying statistical parameters:
- Board microprocessor software version
- Number of cycles carried out. If the motors are replaced, take down the
number of manoeuvres carried out up to that time.
- Number of cycles carried out since the latest maintenance operation. It
is automatically set to zero after each self-diagnosing or parameter
writing operation.
- Date of latest maintenance. To be manually updated from the appropriate
"Update maintenance date" menu.
- Installation description. Allows you to enter 16 characters identifying the
installation.
- Number of zone operating units (advanced statistics) Address 16:
indicates the number of actuators belonging to the same zone as that of
the master (only updated in the master boards).
- Number of total operating units (advanced statistics) Address 17:
indicates the number of actuators connected (only updated in the
master boards).

14) SCRAPPING

Warning: This operation should only be carried out by qualified
personnel. Materials must be disposed of in conformity with the current
regulations. In case of scrapping, the automation devices do not entail any
particular risks or danger. In case of materials to be recycled, these should be
sorted out by type (electrical components, copper, aluminium, plastic etc.).

15) DISMANTLING

Warning: This operation should only be carried out by qualified
personnel. When the control unit is disassembled to be reassembled on
another site, proceed as follows:
• Disconnect the power supply and the entire electrical installation.
• In the case where some of the components cannot be removed or are
damaged, they must be replaced.
The descriptions and illustrations contained in the present manual
are not binding. The Company reserves the right to make any alterations
deemed appropriate for the technical, manufacturing and commercial
improvement of the product, while leaving the essential product
features unchanged, at any time and without undertaking to update
the present publication.