Configuration Parameters of the Applicator
4.3
The configuration parameters of the applicator can be found in the menu Setup > Machine param..
Parameter
Applicator
> Mode of oper.
> Mode of appl.
> Waiting
position
> Blow time
> Roll-on time
> Support delay
on
> Support del.
off
> Delay time
> Lock time
> Peel position
> Vacuum control
Table 3
Applicator parameters
Meaning
Configuration parameters of the applicator
Setting the operation mode Stamp on, Roll on, Blow on
Setting the application mode Print-Apply / Apply-Print
Print-Apply:
An external start signal releases the print of a label and following the
application of the label. After a cycle is complete, the pad without label
waits in the start position.
Apply-Print:
An extra signal starts the print of the first label and the transfer of the
label to the pad. The external start signal releases the application of
the label and following the print and transfer of the next label.
After a cycle is complete, the pad with a label is in the waiting
position.
only at Mode of oper. Blow on and Mode of appl. Apply-Print
up : Pad waits in the start position for the start signal
down : Pad waits in the labelling position for the start signal
only at Mode of oper. Blow on
Switch-on time (max. 2,5 s) of the blowing air for the label transfer
only at Mode of oper. Roll on
Dwell time (max. 5 s) of the pad in the labelling position
Setting the switch-on delay (max. 2,5 s) for the supporting air between
print start and switching on the supporting air. The delay prevents
swirling at the front of the label and, consequently, avoids faults when
the label is being picked up from the printer.
Setting the switch-off delay (max. 2,5 s) for the supporting air between
the end of label forwarding and switching on the supporting air. The
delay can be useful to separate the rear edge of the label from the
carrier to avoid errors and to improve the accuracy of label positioning
Delay (max. 2,5 s) between start signal and the start of an labelling
cycle.
Allows e.g. the use of product sensors at conveyors.
All start signals coming in following the first start signal are ignored
when they arrive within the lock time.
Shift the position of the dispensed label relatively to the dispense
edge. In the software an extra peel offset value is available. The
offset values from "Peel position" and from software are added
together for execution.  "Setting the Peel Position".
Setting the label transfer check from printer to pad and from pad to
product by the vacuum sensor
14
Default
Stamp on
Print-
Apply
up
0 ms
0 ms
0 ms
270 ms
0 ms
0 ms
0,0 mm
On