3.5

Mounting the Pad

1
2
3
4
5
Fig. 12
Mounting the pad
1. Pull the tube (6) out of the push-in-fitting
2. Insert the pin (5) on the pad (8) into the hole on the bottom side of the pad holder (7).
3. Fix the pad (8) with the screw (1) at the pad holder (7) and make a rough adjustment of the pad to the printer
dispense plate.
4. Insert the vacuum tube (2) an the blowing air tube into the appropriate push-in-fittings (3,4) of the pad.
5. Insert the tube (6) into the appropriate push-in-fitting on the cylinder.
!
Attention!
 To avoid possible collisions of the pad with other parts of the printer-applicator system, please roughly
align the pad in all directions ( "Mechanical Adjustments") before connecting the applicator to the
compressed air supply !
3.6

Mounting the Stopper

1 2 3
Fig. 13
Mounting the stopper
When the applicator is delivered, the stopper (1) is mounted on the rods (4). With this stopper the labelling position
for the operation mode "Blow on" can be adjusted.
In the operation modes "Stamp on" and "Roll on" the stopper is not needed.
Operation modes "Stamp on" and "Roll on"
 Loosen the screw (3) at the stopper (1).
 Slide the stopper (1) as far as possible upwards and tighten the screw (3). The stopper must not limit the pad
movement.
or
Remove the stopper (1) upwards from the rods (4).
Operation mode "Blow on"
 If necessary, slide the stopper (1) with the rubber buffer (2) down onto the rods (4).
 Adjust the stopper (1)  ''Adjusting the Stopper''.