Lenovo ThinkSystem ST550 7X09 Maintenance Manual page 54

Table of Contents

Advertisement

Server model: sixteen 2.5-inch SAS/SATA drives, four 2.5-inch SAS/SATA/NVMe drives, one 24i RAID
adapter, one NVMe adapter
Notes:
• Ensure that all cables are routed through the correct cable clips.
• Broken lines indicate the hidden parts.
Figure 27. Cable routing for server models with sixteen 2.5-inch SAS/SATA drives, four 2.5-inch SAS/SATA/NVMe drives,
one 24i RAID adapter, and one NVMe adapter
Cable
1
NVMe signal cable for
backplane 1
2
SAS signal cable for
backplane 1
3
Power cable for backplane 1
46
ThinkSystem ST550 Maintenance Manual
From
NVMe 0, NVMe 1, NVMe 2, and NVMe 3
connectors on backplane 1
SAS 0 and SAS 1 connectors on
backplane 1
Power connector on backplane 1
To
C0, C1, C2, and C3 connectors on the
NVMe adapter
C0 and C1 connectors on the 24i RAID
adapter
Backplane 1 power connector on the
system board

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Thinksystem st550 7x10

Table of Contents