Code List - Hitachi L300P-110L Instruction Manual

L300p series three phase input 200/400v class
Table of Contents

Advertisement

4.2 Code list

Monitor code
Dis-
play
Function name
code
Output frequency
d001
monitor
Output current
d002
monitor
Operation direction
d003
monitor
PID feedback
d004
monitor
Intelligent input
d005
terminal monitor
Intelligent output
d006
terminal monitor
Frequency
d007
conversion monitor
Output voltage
d013
monitor
Electric power
d014
monitor
Accumulated time
d016
monitor during RUN
Power ON time
d017
monitor
Number of trip time
d080
monitor
d081
Trip monitor 1
d082
Trip monitor 2
d083
Trip monitor 3
d084
Trip monitor 4
d085
Trip monitor 5
d086
Trip monitor 6
d090
Warning monitor
Output
frequency
F001
setting
st
F002
1
acceleration time
nd
F202
acceleration time
2
F003
st
deceleration time
1
F203
nd
deceleration time
2
Operation direction
F004
selection
(Note 1) Change mode during run by selection of b031 (software lock selection).
(Note) Do not forget to press "STR" key when you change the display.
L300P monitor or data range
(digital operator)
0.00-99.99/100.0-400.0(Hz)
0.0-999.9(A)
F(forward)/o(stop)/r(reverse)
0.00-99.99/100.0-999.9/1000. -9999. /
1000-9999/ 100- 999 (10000-99900)
(Example) FW, terminal2, and 1: ON
FW
ON
OFF
5 4
3 2
1
(Example) Terminal2, 1:ON
ON
OFF
AL
12 11
0.00-99.99/100.0-999.9/1000. –9999. /
1000-3996
0.0-600.0 V
0.0-999.9 kW
0.-9999./1000-9999/ 100- 999 h
0.-9999./1000-9999/ 100- 999 h
0.-9999./1000-6553(10000-65530) (time)
Trip Code, frequency(Hz), current(A),
voltage(V),RUN time(h) power ON time(h)
Trip Code, frequency(Hz), current(A),
voltage(V),RUN time(h) power ON time(h)
Trip Code, frequency(Hz), current(A),
voltage(V),RUN time(h) power ON time(h)
Trip Code, frequency(Hz), current(A),
voltage(V),RUN time(h) power ON time(h)
Trip Code, frequency(Hz), current(A),
voltage(V),RUN time(h) power ON time(h)
Trip Code, frequency(Hz), current(A),
voltage(V),RUN time(h) power ON time(h)
Warning code
0.0, starting frequency-Max. frequency
nd
(2
max. frequency)(Hz)
0.01-99.99/100.0-999.9/1000.-3600.(s)
0.01-99.99/100.0-999.9/1000. -3600. (s)
0.01-99.99/100.0-999.9/1000. -3600. (s)
0.01-99.99/100.0-999.9/1000. -3600. (s)
00(forward)/01(reverse)
4-5
Chapter 4 Explanation of function
Initial
data
Terminal 5, 4, 3
:OFF
AL
:OFF
0.00
30.00
30.00
30.00
30.00
00
(Note 1)
Change
Setting
mode
on
during
running
running
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Page
4-10
4-10
4-10
4-10
4-11
4-11
4-12
4-12
4-12
4-13
4-13
4-13
4-13
4-13
4-13
4-13
4-13
4-13
4-78
4-14
4-16
4-16
4-16
4-16
4-15

Advertisement